| 1226 | AxyaLoop® 3mm Titanium Suture Implant, Preloaded with Size 2 Green Nylon Non-Needled Suture | Sterile, Single Use | ||||||||
The 3mm implant incorporates a unique thread design with an easy glide eyelet for maximum pull out strength in bone. The vertical laser mark on the distal part of the insertion shaft indicates the orientation of the suture eyelets. When the implant is inserted, the vertical laser mark should point toward the labral tissue to ensure the sutures slide smoothly through the tissue and eyelet, minimizing suture abrasion and sliding resistance. All implants are supplied sterile and preloaded with a single USP size 2 nylon suture.

| 1227 | AxyaLoop® 5mm Titanium Suture Implant, Preloaded with Size 2 Green and Light Green Nylon Non-Needled Suture | Sterile, Single Use | ||||||||
The 5mm implant incorporates a unique self starting thread design with an easy glide eyelet for maximum pull out strength in bone. The vertical laser mark on the distal part of the insertion shaft indicates the orientation of the suture eyelets. When the implant is inserted, the vertical laser mark should point toward the cuff tendon to ensure the sutures slide smoothly through the tissue and eyelet, minimizing suture abrasion and sliding resistance. All implants are supplied sterile and preloaded with two USP size 2 nylon sutures.

| 1238 | AxyaLoop® 6.5mm Titanium Suture Implant, Preloaded with Size 2 Green and Light Green Nylon Non-Needled Suture | Sterile, Single Use | ||||||||
The 6.5mm implant incorporates a unique self starting thread design with an easy glide eyelet for maximum pull out strength in bone. The vertical laser mark on the distal part of the insertion shaft indicates the orientation of the suture eyelets. When the implant is inserted, the vertical laser mark should point toward the cuff tendon to ensure the sutures slide smoothly through the tissue and eyelet, minimizing suture abrasion and sliding resistance. All implants are supplied sterile and preloaded with two USP size 2 nylon sutures.

| 1230 | AxyaLoop® 3mm Bioabsorbable Suture Implant, Preloaded with Size 2 Green and Light Green Nylon Non-Needled Suture | Sterile, Single Use | ||||||||
The 3mm bioabsorbable implant incorporates unique, patented, elliptical, suture friendly eyelets designed to be inserted flush with the cortical surface to maximize fixation strength and anchor stability. The vertical laser mark on the distal part of the insertion shaft indicates the orientation of the sutures eyelets.
When the implant is inserted, the vertical laser mark should point toward the labral tissue to ensure the sutures slide smoothly through the tissue and eyelet, minimizing suture abrasion and sliding resistance. It is constructed of non-metallic, non-reflective, radiolucent Poly L-Lactide (PLLA). The implant has two individual eyelets to eliminate suture binding. The implants are supplied sterile and preloaded with two USP size 2 nylon sutures.

| 1234 | AxyaLoop® 5mm Bioabsorbable Suture Implant, Preloaded with Size 2 Green and Light Green Nylon Non-Needled Suture | Sterile, Single Use | ||||||||
The 5mm Bioabsorbable implant incorporates unique, patented, elliptical, suture friendly eyelets designed to be inserted flush with the cortical bone surface to maximize fixation strength and anchor stability. The vertical laser mark on the distal part of the insertion shaft indicates the orientation of the sutures eyelets.
When the implant is inserted, the vertical laser mark should point toward the cuff tendon to ensure the sutures slide smoothly through the tissue and eyelet, minimizing suture abrasion and sliding resistance. It is constructed of non-metallic, non-reflective, radiolucent Poly L-Lactide (PLLA). The implant has two individual eyelets to eliminate suture binding. The implants are supplied sterile and preloaded with two USP size 2 nylon sutures.

| 1265 | AxyaLoop® 6.5mm Bioabsorbable Suture Implant, Preloaded with Size 2 Green and Light Green Nylon Non-Needled Suture | Sterile, Single Use | ||||||||
The 6.5mm Bioabsorbable implant incorporates unique, patented, elliptical, suture friendly eyelets designed to be inserted flush with the cortical bone surface to maximize fixation strength and anchor stability. The vertical laser mark on the distal part of the insertion shaft indicates the orientation of the sutures eyelets.
When the implant is inserted, the vertical laser mark should point toward the cuff tendon to ensure the sutures slide smoothly through the tissue and eyelet, minimizing suture abrasion and sliding resistance. It is constructed of non-metallic, non-reflective, radiolucent Poly L-Lactide (PLLA). The implant has two individual eyelets to eliminate suture binding. The implants are supplied sterile and preloaded with two USP size 2 nylon sutures.

| 1270 | Fixation Sleeve and AxyaLoop® 5mm Titanium Suture Implant, Preloaded with Size 2 Green and Light Green Nylon Non-Needled Suture | Sterile, Single Use | ||||||||
The disposable sleeve delivers and welds USP size 2 nylon to the surgical site.
The 5mm Bioabsorbable implant incorporates unique, patented, elliptical, suture friendly eyelets designed to be inserted flush with the cortical bone surface to maximize fixation strength and anchor stability. The vertical laser mark on the distal part of the insertion shaft indicates the orientation of the sutures eyelets.
The 5mm implant incorporates a unique self starting thread design with an easy glide eyelet for maximum pull out strength in bone. The vertical laser mark on the distal part of the insertion shaft indicates the orientation of the sutures eyelets. When the implant is inserted, the vertical laser mark should point toward the cuff tendon to ensure the sutures slide smoothly through the tissue and eyelet, minimizing suture abrasion and sliding resistance. All implants are supplied sterile and preloaded with two USP size 2 nylon sutures.

| 1271 | Fixation Sleeve and AxyaLoop® 5mm Bioabsorbable Suture Implant, Preloaded with Size 2 Green and Light Green Nylon Non-Needled Suture | Sterile, Single Use | ||||||||
The disposable sleeve delivers and welds USP size 2 nylon suture to the surgical site.
The 5mm Bioabsorbable implant incorporates unique, patented, elliptical, suture friendly eyelets designed to be inserted flush with the cortical bone surface to maximize fixation strength and anchor stability. The vertical laser mark on the distal part of the insertion shaft indicates the orientation of the sutures eyelets.
When the implant is inserted, the vertical laser mark should point toward the cuff tendon to ensure the sutures slide smoothly through the tissue and eyelet, minimizing suture abrasion and sliding resistance. It is constructed of non-metallic, non-reflective, radiolucent Poly L-Lactide (PLLA). The implant has two individual eyelets to eliminate suture binding. The implants are supplied sterile and preloaded with two USP size 2 nylon sutures.

| 1273 | Fixation Sleeve and AxyaLoop® 3mm Bioabsorbable Suture Implant, Preloaded with Size 2 Green and Light Green Nylon Non-Needled Suture | Sterile, Single Use | ||||||||
The disposable sleeve delivers and welds USP size 2 nylon suture to the surgical site.
The 3mm bioabsorbable implant incorporates unique, patented, elliptical, suture friendly eyelets designed to be inserted flush with the cortical surface to maximize fixation strength and anchor stability. The vertical laser mark on the distal part of the insertion shaft indicates the orientation of the sutures eyelets.
When the implant is inserted, the vertical laser mark should point toward the labral tissue to ensure the sutures slide smoothly through the tissue and eyelet, minimizing suture abrasion and sliding resistance. It is constructed of non-metallic, non-reflective, radiolucent Poly L-Lactide (PLLA). The implant has two individual eyelets to eliminate suture binding. The implants are supplied sterile and preloaded with two USP size 2 nylon sutures.

| 1274 | Fixation Sleeve and AxyaLoop® 3mm Titanium Suture Implant, Preloaded with Size 2 Green Nylon Non-Needled Suture | Sterile, Single Use | ||||||||
The disposable sleeve delivers and welds USP size 2 nylon suture to the surgical site.
The 3mm implant incorporates a unique thread design with an easy glide eyelet for maximum pull out strength in bone. The vertical laser mark on the distal part of the insertion shaft indicates the orientation of the suture eyelets. When the implant is inserted, the vertical laser mark should point toward the labral tissue to ensure the sutures slide smoothly through the tissue and eyelet, minimizing suture abrasion and sliding resistance. All implants are supplied sterile and preloaded with a single USP size 2 nylon suture.





